Amphenol post-treatment pressure sensor
Source:本站Time:2019/5/21 11:39:35
Amphenol post-treatment pressure sensor parameters:
1、working pressure: 0 ~ 1MPa
2、Overpressure: 2 MPa
3、explosion pressure: 3 MPa
4、working temperature: -10 ~ 105 ̊C
5、Accuracy: +/-2 %Vcc @ -10 ~ 105 ̊C
6、power supply: 5+/-0.25 VDC
7、output: 0.5 ~ 4.5 VDC
8、Medium: 32.5% urea
Amphenol Post-Processing Pressure Sensor Features:
1、Post-treatment liquid level monitoring
2、Post-treatment syringe pump pressure monitoring
Amphenol post-treatment pressure sensor features:
1、MEMS t technology, high precision
2、contact medium surface stainless steel material, multi-media compatibility
3、high reliability